This text came with the file. It may have mistakes. When the text and the image disagree, the image is right.
84 was dlll."ing t ape dumps, it would go up a.nd then come b&ok down but we lrnew this before flight though. Comfort dq a.nd night, with and without suits .. .There is just no com parison.. I have the notes that I wrote down while we were still up there. There is no comparison between suit on and suit off operation. The suit off is 1,000 per cent better. I think I may have been conservative. It wa.s ma.ybe a lot better than tha.t. Comfort without the suits was by and large very good. We used the cabin fan only once in the entire mission during one of the checks with the suit off. This was when we had Jim's ■uit inlet hose blocked off &nd my inl et hose operating in my side &nd the two suit outlet hoses in my side of the spacecraft. As we already mentioned here, Jim noticed some stagnant areas in the ap&oecra.ft, and • we turned on the cabin fan to see if this aleviated the pro blem, and it did help. There was a definite circulation with the cabin fan on. The only problem is the cabin £an draws a considerable electrical load, and we did not have the power to run it continually. The cabin pressure r egu lator worked perfectly, it never worked at all. Lovell That is right, never heard it, thank goodness. :Borman That's the pressure relief valve. Right, never hea.rd it. It never actuated. The cabin pressure regulator was ae