98
Borman
The onboard cues for monitoring the el ectrical system are
adequate.
We found out one thing in this f light , t hat is
the Delt a Plight s really don't mean a lot.
We had been
told before the flight never to purge if you had a Delta P
light. We ended up violating every single one of t he ca.r-­
dinal rules that we had.
I think the t hing to note about the entire electrical
syst em was the f ine work done on the ground.
They came up
with solutions. They evidently were running similar type
cel ls at MAC, St. Louis, and they kept them working
f or l onger than they should have.
Fuel cel l operation, as far as I was concerned, Section 1
was i deal. Section 1 maintained its share of the load the
whole flight. Section 2, we lost stacks 2-A and 2-C
event ual l y, I believe on about the 12th day.
I was a
little concerned on the 13th day with the status of Secti on 1
because we had had a delta Plight on Section 1 f or the
first time and we had been running almost 24 hours.
But, t he ground came through and read us up a technical
report from St. Louis that explained the whol e thing.
It
made me feel a lot easier when they did that. Rather than
having t he ground comment blindly on it, "the fuel cells
are going to be good for 24 hours," I would like t o get a